TY - GEN
T1 - Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
AU - Huang, Shoujin
AU - Luo, Guanxiong
AU - Wang, Xi
AU - Chen, Ziran
AU - Wang, Yuwan
AU - Yang, Huaishui
AU - Heng, Pheng Ann
AU - Zhang, Lingyan
AU - Lyu, Mengye
N1 - Publisher Copyright:
© The Author(s), under exclusive license to Springer Nature Switzerland AG 2024.
PY - 2024
Y1 - 2024
N2 - In general, diffusion model-based MRI reconstruction methods incrementally remove artificially added noise while imposing data consistency to reconstruct the underlying images. However, real-world MRI acquisitions already contain inherent noise due to thermal fluctuations. This phenomenon is particularly notable when using ultra-fast, high-resolution imaging sequences for advanced research, or using low-field systems favored by low- and middle-income countries. These common scenarios can lead to sub-optimal performance or complete failure of existing diffusion model-based reconstruction techniques. Specifically, as the artificially added noise is gradually removed, the inherent MRI noise becomes increasingly pronounced, making the actual noise level inconsistent with the predefined denoising schedule and consequently inaccurate image reconstruction. To tackle this problem, we propose a posterior sampling strategy with a novel NoIse Level Adaptive Data Consistency (Nila-DC) operation. Extensive experiments are conducted on two public datasets and an in-house clinical dataset with field strength ranging from 0.3T to 3T, showing that our method surpasses the state-of-the-art MRI reconstruction methods, and is highly robust against various noise levels. The code for Nila is available at https://github.com/Solor-pikachu/Nila.
AB - In general, diffusion model-based MRI reconstruction methods incrementally remove artificially added noise while imposing data consistency to reconstruct the underlying images. However, real-world MRI acquisitions already contain inherent noise due to thermal fluctuations. This phenomenon is particularly notable when using ultra-fast, high-resolution imaging sequences for advanced research, or using low-field systems favored by low- and middle-income countries. These common scenarios can lead to sub-optimal performance or complete failure of existing diffusion model-based reconstruction techniques. Specifically, as the artificially added noise is gradually removed, the inherent MRI noise becomes increasingly pronounced, making the actual noise level inconsistent with the predefined denoising schedule and consequently inaccurate image reconstruction. To tackle this problem, we propose a posterior sampling strategy with a novel NoIse Level Adaptive Data Consistency (Nila-DC) operation. Extensive experiments are conducted on two public datasets and an in-house clinical dataset with field strength ranging from 0.3T to 3T, showing that our method surpasses the state-of-the-art MRI reconstruction methods, and is highly robust against various noise levels. The code for Nila is available at https://github.com/Solor-pikachu/Nila.
KW - Diffusion model
KW - Image reconstruction
KW - Parallel imaging
UR - https://www.scopus.com/pages/publications/85212493081
U2 - 10.1007/978-3-031-72104-5_48
DO - 10.1007/978-3-031-72104-5_48
M3 - Conference contribution
AN - SCOPUS:85212493081
SN - 9783031721038
T3 - Lecture Notes in Computer Science
SP - 498
EP - 508
BT - Medical Image Computing and Computer Assisted Intervention – MICCAI 2024 - 27th International Conference, Proceedings
A2 - Linguraru, Marius George
A2 - Dou, Qi
A2 - Feragen, Aasa
A2 - Giannarou, Stamatia
A2 - Glocker, Ben
A2 - Lekadir, Karim
A2 - Schnabel, Julia A.
PB - Springer Science and Business Media Deutschland GmbH
T2 - 27th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2024
Y2 - 6 October 2024 through 10 October 2024
ER -