TY - GEN
T1 - MR-IQ Metric
T2 - 23rd IEEE International Symposium on Biomedical Imaging, ISBI 2026
AU - Kanli, Georgia
AU - Boudissa, Selma
AU - Gamizi, Salah
AU - Palissot, Valérie
AU - Jiřik, Radovan
AU - Keunen, Olivier
N1 - Publisher Copyright:
© 2026 IEEE.
PY - 2026/5/20
Y1 - 2026/5/20
N2 - Objective and reproducible evaluation of magnetic resonance imaging (MRI) quality remains challenging in the absence of reliable reference data. We introduce MR-IQ, a novel open-source, reference-free metric for quantitative MRI quality assessment. MR-IQ combines three normalized sub-metrics: the normalised signal-to-noise ratio (nSNR), sharpness index (SI), and artefact-free index (AFI). These three sub-metrics are integrated into a single composite score via a harmonic mean formulation. As a first validation study, we evaluate MR-IQ exclusively on preclinical MRI data, using datasets with simulated noise, blur, and motion artefacts. The results demonstrate that MR-IQ provides consistent and interpretable quality scores that are qualitatively consistent with perceived anatomical degradation, outperforming conventional blind metrics such as BRISQUE. The proposed metric enables quantitative, artefact-sensitive, and reproducible evaluation of MRI data, facilitating its integration into automated quality-control pipelines and AIbased reconstruction workflows.
AB - Objective and reproducible evaluation of magnetic resonance imaging (MRI) quality remains challenging in the absence of reliable reference data. We introduce MR-IQ, a novel open-source, reference-free metric for quantitative MRI quality assessment. MR-IQ combines three normalized sub-metrics: the normalised signal-to-noise ratio (nSNR), sharpness index (SI), and artefact-free index (AFI). These three sub-metrics are integrated into a single composite score via a harmonic mean formulation. As a first validation study, we evaluate MR-IQ exclusively on preclinical MRI data, using datasets with simulated noise, blur, and motion artefacts. The results demonstrate that MR-IQ provides consistent and interpretable quality scores that are qualitatively consistent with perceived anatomical degradation, outperforming conventional blind metrics such as BRISQUE. The proposed metric enables quantitative, artefact-sensitive, and reproducible evaluation of MRI data, facilitating its integration into automated quality-control pipelines and AIbased reconstruction workflows.
UR - https://www.scopus.com/pages/publications/105041673178
U2 - 10.1109/ISBI61048.2026.11515439
DO - 10.1109/ISBI61048.2026.11515439
M3 - Conference contribution
AN - SCOPUS:105041673178
T3 - Proceedings - International Symposium on Biomedical Imaging
BT - ISBI 2026 - 23rd IEEE International Symposium on Biomedical Imaging
PB - IEEE Computer Society
Y2 - 8 April 2026 through 11 April 2026
ER -