TY - JOUR
T1 - Method Validation for Extraction of Nucleic Acids from Peripheral Whole Blood
AU - Mathay, Conny
AU - Hamot, Gaël
AU - Henry, Estelle
AU - Mommaerts, Kathleen
AU - Thorlaksdottir, Audur
AU - Trouet, Johanna
AU - Betsou, Fay
N1 - Publisher Copyright:
© 2016, Mary Ann Liebert, Inc.
PY - 2016/12/1
Y1 - 2016/12/1
N2 - Background: This article is the fifth in a series of publications providing formal method validation for biospecimen processing. We report the optimization and validation of methodology to obtain nucleic acids of sufficient quantity and quality from blood. Methods: DNA was extracted using the Chemagic DNA Blood Kit on an MSM I. Extraction was optimized in terms of blood volume, elution buffer volume, and lysis conditions. The optimal protocol was validated for reproducibility, robustness (delay to buffy coat extraction, blood vs. buffy coat, and use of a magnetic rack), and performance (yield, purity, and concentration). RNA was extracted using a PAXgene Blood miRNA kit with a QiaCube. The protocol was validated for reproducibility, robustness (elution buffer, delay, and temperature before extraction), and performance (yield, purity, integrity, and miRNA content). Two platforms (QiaCube, Biorobot Universal) were further compared. Results: For DNA extraction, a 4 mL blood sample, manual lysis, and 300 μL elution buffer were found to be reproducible (CV <10% for DNA yield and A260 nm/A280 nm ratio) and robust (buffy coat vs. whole blood; immediate processing of buffy coat after lysis vs. storage for 1 week at 2-8°C; and magnetic rack use). There was no difference between automated and manual lysis. RNA extracted with the PAXgene Blood miRNA kit on a QiaCube gave high yields and optimal reproducibility (low CV for RNA yield and integrity) with BR5 elution buffer (vs. water and TE). PAXgene tubes could be stored for up to 2 weeks at 2-8°C. The Biorobot Universal System gave similar mean RNA yields with Qiacube and slightly lower but acceptable purity. Conclusions: We validated automated isolation of DNA with a Chemagic DNA Blood Kit on a magnetic bead-based MSM I, and of RNA with a PAXgene Blood miRNA kit on a silica membrane-based QiaCube or Biorobot (for low and high throughput, respectively).
AB - Background: This article is the fifth in a series of publications providing formal method validation for biospecimen processing. We report the optimization and validation of methodology to obtain nucleic acids of sufficient quantity and quality from blood. Methods: DNA was extracted using the Chemagic DNA Blood Kit on an MSM I. Extraction was optimized in terms of blood volume, elution buffer volume, and lysis conditions. The optimal protocol was validated for reproducibility, robustness (delay to buffy coat extraction, blood vs. buffy coat, and use of a magnetic rack), and performance (yield, purity, and concentration). RNA was extracted using a PAXgene Blood miRNA kit with a QiaCube. The protocol was validated for reproducibility, robustness (elution buffer, delay, and temperature before extraction), and performance (yield, purity, integrity, and miRNA content). Two platforms (QiaCube, Biorobot Universal) were further compared. Results: For DNA extraction, a 4 mL blood sample, manual lysis, and 300 μL elution buffer were found to be reproducible (CV <10% for DNA yield and A260 nm/A280 nm ratio) and robust (buffy coat vs. whole blood; immediate processing of buffy coat after lysis vs. storage for 1 week at 2-8°C; and magnetic rack use). There was no difference between automated and manual lysis. RNA extracted with the PAXgene Blood miRNA kit on a QiaCube gave high yields and optimal reproducibility (low CV for RNA yield and integrity) with BR5 elution buffer (vs. water and TE). PAXgene tubes could be stored for up to 2 weeks at 2-8°C. The Biorobot Universal System gave similar mean RNA yields with Qiacube and slightly lower but acceptable purity. Conclusions: We validated automated isolation of DNA with a Chemagic DNA Blood Kit on a magnetic bead-based MSM I, and of RNA with a PAXgene Blood miRNA kit on a silica membrane-based QiaCube or Biorobot (for low and high throughput, respectively).
KW - DNA
KW - Method validation
KW - RNA
KW - processing method
KW - whole blood
UR - http://www.scopus.com/inward/record.url?scp=85005958935&partnerID=8YFLogxK
U2 - 10.1089/bio.2016.0011
DO - 10.1089/bio.2016.0011
M3 - Article
C2 - 27548617
AN - SCOPUS:85005958935
SN - 1947-5535
VL - 14
SP - 520
EP - 529
JO - Biopreservation and Biobanking
JF - Biopreservation and Biobanking
IS - 6
ER -