T1 - Ligament graff initial fixation strength using biodegradable interference screws
AU - Rupp, Stefan
AU - Seil, Romain
AU - Schneider, Annette
AU - Kohn, Dieter M.
PY - 1999
Y1 - 1999
N2 - The objective of this study was to evaluate the initial fixation strength of three types of biodegradable interference screws [an Endo Fix, 7 X 25 mm polyglycolic acid, non-self-tapping (Acufex); a biodegradable interference screw, 7 x 23 mm poly-L-lactic acid, self-tapping (Arthrex); a Bioscrew, 7 x 25 mm poly-L-lactic acid, self-tapping (Linvatec)] in comparison to a titanium interference screw (Linvatec, 7 x 25 mm) in anterior cruciate ligament reconstruction using a bone-patellar tendon, bone graft. Porcine lower limbs were used. To control for specimen related bias, bone mineral density of each tibia was measured. All specimens were loaded to failure. Failure mode was determined by visual analysis. The maximum load to failure [mean (SD)] was 785 (87) N (titanium screw), 555 (60) N (Acufex), 592 (211) N (Arthrex), and 844 N (Linvatec). The primary fixation strength of the titanium screw and the Linvatec screw was significantly higher (p < 0.05) than the primary fixation strength of the Arthrex screw and the Acufex screw. There was no difference in bone mineral density between the groups. With respect to primary fixation strength, all biodegradable screws were strong enough to allow accelerated rehabilitation. From this point of view the biodegradable screws may be a reasonable alternative to titanium interference screws.
AB - The objective of this study was to evaluate the initial fixation strength of three types of biodegradable interference screws [an Endo Fix, 7 X 25 mm polyglycolic acid, non-self-tapping (Acufex); a biodegradable interference screw, 7 x 23 mm poly-L-lactic acid, self-tapping (Arthrex); a Bioscrew, 7 x 25 mm poly-L-lactic acid, self-tapping (Linvatec)] in comparison to a titanium interference screw (Linvatec, 7 x 25 mm) in anterior cruciate ligament reconstruction using a bone-patellar tendon, bone graft. Porcine lower limbs were used. To control for specimen related bias, bone mineral density of each tibia was measured. All specimens were loaded to failure. Failure mode was determined by visual analysis. The maximum load to failure [mean (SD)] was 785 (87) N (titanium screw), 555 (60) N (Acufex), 592 (211) N (Arthrex), and 844 N (Linvatec). The primary fixation strength of the titanium screw and the Linvatec screw was significantly higher (p < 0.05) than the primary fixation strength of the Arthrex screw and the Acufex screw. There was no difference in bone mineral density between the groups. With respect to primary fixation strength, all biodegradable screws were strong enough to allow accelerated rehabilitation. From this point of view the biodegradable screws may be a reasonable alternative to titanium interference screws.
KW - Biomechanics
KW - Interference screw
KW - Patellar tendon autograft
KW - Poly-L-lactic acid
KW - Press fit
UR - http://www.scopus.com/inward/record.url?scp=0032588699&partnerID=8YFLogxK
U2 - 10.1002/(SICI)1097-4636(1999)48:1<70::AID-JBM12>3.0.CO;2-P
DO - 10.1002/(SICI)1097-4636(1999)48:1<70::AID-JBM12>3.0.CO;2-P
M3 - Article
C2 - 10029152
AN - SCOPUS:0032588699
SN - 0021-9304
VL - 48
SP - 70
EP - 74
JO - Journal of Biomedical Materials Research
JF - Journal of Biomedical Materials Research
IS - 1
ER -