TY - JOUR
T1 - Diagnostic accuracy of two rK39 antigen-based dipsticks and the formol gel test for rapid diagnosis of visceral leishmaniasis in northeastern Uganda
AU - Chappuis, François
AU - Mueller, Yolanda
AU - Nguimfack, Alexandre
AU - Rwakimari, John Bosco
AU - Couffignal, Sophie
AU - Boelaert, Marleen
AU - Cavailler, Philippe
AU - Loutan, Louis
AU - Piola, Patrice
PY - 2005/12
Y1 - 2005/12
N2 - The development of an accurate, practical, and affordable diagnostic test is essential to improve the management of visceral leishmaniasis (VL) in remote health centers. We evaluated the Formol Gel test (FGT) and two rK39 antigen-based dipsticks, the DUAL-IT L/M, and the Kalazar Detect for VL diagnosis in Amudat Hospital in Uganda. The DUAL-IT L/M was also evaluated for the diagnosis of malaria. All patients clinically suspect of VL were prospectively included in the study between October 2003 and March 2004. The gold standard used to define a VL case was a positive spleen aspirate or a direct agglutination test titer of > 1:12,800 with an appropriate clinical response to antileishmanial therapy. A total of 131 VL and 112 non-VL patients were included in the analysis. The DUAL IT L/M was found to be more sensitive than the Kalazar Detect: 97% (95% confidence interval [95%CI] = 92 to 99%) versus 82% (95%CI = 74 to 87%). The Kalazar Detect and the DUAL IT L/M were highly specific (99% [95%CI = 95 to 100%] and 97% [95%CI = 92 to 99%], respectively). The FGT lacked both sensitivity (66% [95%CI = 57 to 73%]) and specificity (90% [95%CI = 83 to 94%]). The sensitivity of the DUAL IT L/M for malaria was only 57% (95%CI = 37 to 76%). The two rK39 dipsticks can be used for diagnostic confirmation of VL in this region. The DUAL-IT L/M without its malaria diagnostic component (DiaMed-IT LEISH) will be adopted as first-line test for VL in Uganda.
AB - The development of an accurate, practical, and affordable diagnostic test is essential to improve the management of visceral leishmaniasis (VL) in remote health centers. We evaluated the Formol Gel test (FGT) and two rK39 antigen-based dipsticks, the DUAL-IT L/M, and the Kalazar Detect for VL diagnosis in Amudat Hospital in Uganda. The DUAL-IT L/M was also evaluated for the diagnosis of malaria. All patients clinically suspect of VL were prospectively included in the study between October 2003 and March 2004. The gold standard used to define a VL case was a positive spleen aspirate or a direct agglutination test titer of > 1:12,800 with an appropriate clinical response to antileishmanial therapy. A total of 131 VL and 112 non-VL patients were included in the analysis. The DUAL IT L/M was found to be more sensitive than the Kalazar Detect: 97% (95% confidence interval [95%CI] = 92 to 99%) versus 82% (95%CI = 74 to 87%). The Kalazar Detect and the DUAL IT L/M were highly specific (99% [95%CI = 95 to 100%] and 97% [95%CI = 92 to 99%], respectively). The FGT lacked both sensitivity (66% [95%CI = 57 to 73%]) and specificity (90% [95%CI = 83 to 94%]). The sensitivity of the DUAL IT L/M for malaria was only 57% (95%CI = 37 to 76%). The two rK39 dipsticks can be used for diagnostic confirmation of VL in this region. The DUAL-IT L/M without its malaria diagnostic component (DiaMed-IT LEISH) will be adopted as first-line test for VL in Uganda.
UR - http://www.scopus.com/inward/record.url?scp=30744477758&partnerID=8YFLogxK
UR - https://pubmed.ncbi.nlm.nih.gov/16333084/
U2 - 10.1128/JCM.43.12.5973-5977.2005
DO - 10.1128/JCM.43.12.5973-5977.2005
M3 - Article
C2 - 16333084
AN - SCOPUS:30744477758
SN - 0095-1137
VL - 43
SP - 5973
EP - 5977
JO - Journal of Clinical Microbiology
JF - Journal of Clinical Microbiology
IS - 12
ER -